Solution

Collapse and subsidence

Author: admin Posted: 2020-04-01 15:05:04 View: 365

Phenomenon: the sponge rises to the height of 60%-70% and collapses immediately when it reaches the bubble point. It is commonly found in high POP and high powder sponge. The reaction is fast and the gel is insufficient in the later stage.

 

Solutions: 1. Check the quality and output of silicone oil; 2. Check the quality and output of tin catalyst; 3. Consider the delay of amine

 

Phenomenon: it didn't rise to the highest point. It was 7 meters long, but it didn't collapse until 13-15 meters

 

Solution: 1. Focus on checking whether polyether is mixed with impurities or has quality problems

 

Phenomenon: sponge does not react after startup

 

Solution: check whether water and TDI output

 

Phenomenon: the sponge does not react and boiling bubbles appear after startup

 

Solution: check whether the silicone oil is output

 